Test Name:Phospholipase A2 receptor autoantibodies, IgG
Test Number:994
Collect:0.5 mL serum - SST
Minimum Volume:0.2 mL
Note: this volume does not allow for repeat testing
Alternate Collect:0.5 mL serum - red
Container:Serum separator (SST) tube or
LabCorp 12mL plastic transport tube labelled as serum
Processing:SST – spin
Red – spin and separate
Transport/Stability:Ambient (preferred) - 14 days
Refrigerated - 14 days
Frozen - 14 days
Alternate Names:Antibodies to the M-type Phospholipase A2 Receptor
Anti-PLA2R

MSO
LAB994
Performing Lab:LabCorp Burlington (141330); R-NX
Days Set Up:Th
Expected TAT:1 - 7 days
Ref. Ranges:0.0 - 19.9 RU/mL
Collection/
Processing Details:
Useful for:
The anti-PLA2R ELISA (IgG) test kit is intended for the qualitative or semiquantitative determination of IgG class autoantibodies against phospholipase A2 receptor (PLA2R) in human serum.1 It is used as an aid in the diagnosis of primary membranous glomerulonephritis (pMGN), in conjunction with other laboratory and clinical findings.


Method:Enzyme Linked Immunosorbant Assay (ELISA)
CPT Codes:83516
Date Created:05/24/2019
Revised Date:05/24/2019