Allina Health Laboratory a part of Abbott Northwestern Hospital

  



  
    

A | B | C | D | E | F | G | H | I | J | K | L | M
N | O | P | Q | R | S | T | U | V | W | X | Y | Z | Numbers

Test Name:Peanut components allergen profile
Test Number:12468
Collect:2.0 mL serum - SST
Minimum Volume:0.5 mL serum - SST
Alternate Collect:2.0 mL serum - red
2.0 mL Li heparin plasma - PST or
2.0 mL EDTA plasma - lavender
(acceptable, but not preferred)
Container:Serum Separator (SST/gold), PST (lt green) or
AHL False Bottom Screw Cap Serum/Plasma transfer tube
Processing:SST/PST - spin
Red/lavender - spin and separate
Transport/Stability:Refrigerated (preferred) – 7 days
Frozen (OK)
Alternate Names:PEAC
LAB12468
Performing Lab:AHL - Immunology; I-L
Days Set Up:Mo - Fr
Expected TAT:1 - 3 days
Ref. Ranges:<0.10 kU/L
Collection/
Processing Details:
The following components are included in the Peanut Component Panel: f422 (ara h1), f423 (ara h2), f424 (ara h3), f352 (ara h8), f427 (ara h9)
Method:Enzyme-linked Immunosorbent Assay (ELISA)
CPT Codes:86008 x 5
Supply Connection:Allergen request
Additional Information: Allergy class severity values
Date Created:04/09/2014
Revised Date:09/07/2018